IP 68 Cooling Fan
Type II DC & AC lightning protection
AC output 1.1x continuous operation
MPPT efficiency > 99.9%
Intelligent Temperature Control System
Active and reactive power compensation, adjust power factor
Inductor external Effectively reduces the internal temperature of the box, greatly improving product reliability and life. | All aluminum chassis design Full curved surface coverage, making the body lighter and effectively resistant to oxidation and acid and alkali corrosion. |
External WIFI/485/GPRS options Make it easy for users to understand the running status of the machine | Touch button Has high reliability and more sensitive response |
1. The installation method and position must be suitable for the weight and size of the inverter;
2. The inverter must be installed on a solid wall such as a brick wall or a concrete wall to avoid noise or falling when the inverter is running;
3. The installation site should be clearly visible and can be safely accessed without the use of scaffolding and other auxiliary means;
4. In order to facilitate the installation and operation, the installation height of the inverter should be flush with the eye height;
5. The highest altitude of the installation site shall not exceed 2000m, otherwise the inverter may reduce power operation;
6. To ensure that the inverter runs well, the ambient temperature of the installation site should be between -25 ° C ~ +60 ° C;
7. Do not install the inverter in direct sunlight, so as not to cause the temperature is too high, resulting in inverter power down operation;
8. There should be shielding above the inverter;
9. Sufficient effective space should be left around the inverter for good heat dissipation;
10. Vertical installation, wiring area must be down, not allowed to install horizontally; The tilt angle shall not exceed 30 degrees when installed backward; Tilted forward, horizontal and inverted installation is not allowed.
PV Input Data | PIT A40 |
Max. DC Power ( W ) | 60000 |
Max. DC Voltage ( V ) | 1100 |
MPPT Voltage Range ( V ) | 200-1000 |
MPPT Full Power Voltage Range ( V ) | 500-850 |
Rated Input Voltage ( V ) | 620 |
Start-up Voltage ( V ) | 200 |
Max. Input Current ( A ) | 38 x 3 |
Max. Short Current ( A ) | 48 x 2 |
No. of MPP Tracker / No. of PV String | ‘3/6 |
Input Connector Type | MC4 |
AC Output Data | PIT A40 |
Max. Output Power ( VA ) | 44000 |
Nominal Output Power ( W ) | 40000 |
Max. Output Current ( A ) | 65 |
Nominal Output Voltage ( V ) | 3P+N+PE / 3P+PE 230/400 |
Grid Voltage Range | 260Vac-519Vac ( According to local standard ) |
Nominal Output Frequency ( Hz ) | 50/60 |
Grid Frequency Range | 45-55Hz / 55-65Hz ( According to local standard ) |
Output Power Factor | 1 default ( Adjustable from 0.8 leading to 0.8 lagging ) |
Output Current THD | <3% |
Efficiency | PIT A40 |
Max. Efficiency | 98.65% |
Euro Efficiency | 98.25% |
Protection | PIT A40 |
PV Reverse Polarity Protection | YES |
PV Insulation Resistance Detection | YES |
AC Short Circuit Protection | YES |
AC Over Current Protection | YES |
AC Over Voltage Protection | YES |
Anti-lslanding Protection | YES |
Residual Current Detection | YES |
Over Temperature Protection | YES |
Integrated DC switch | YES |
Surge Protection | Integrated ( Type II ) |
Smart IV Curve Scaning | YES |
Quick Arc Fault Circuit Interruption | Optional |
General Data | PIT A40 |
Dimensions ( W x H x D, mm ) | 710 x 470 x 236 |
Weight ( kg ) | 44 |
Protection Degree | IP 65 |
Enclosure Materia | Aluminum |
Ambient Temperature Range ( °C ) | -25 to 60 |
Humidity Range | 0-100% |
Topology | Transformerless |
Communication Interface | RS485 / WiFi / Wire Ethernet / GPRS ( optional ) |
Cooling Concept | Intelligent Fan Cooling |
Noise Emission ( db ) | <51 |
Night Power Consumption ( W ) | <1 |
Max. Operation Altitude ( m ) | ≤4000 |
Certifications and Standards | PIT A40 |
EMC Standard | EN/IEC 61000-6-2, EN/IEC 61000-6-3, EN61000-3-2, EN61000-3-3, EN61000-3-11, EN61000-3-12 |
Safety Standard | IEC 60068, UL1741, EN62109 |
Grid-connection | IEEE1547, CSA C22, EN50549, VDE4105, VDE0126, RD1699, ABNT NBR16149 & 16150, AS4777.2, NB/T32004, G98/G99, IEC61727 |
User name | Member Level | Quantity | Specification | Purchase Date |
---|
WhatsAppContact
Mobile
stations